Circuit breaker Compact NSX160F, 36 KA at 415 VAC, TMD trip unit 160 A, 3 poles

 7,999

range
Compact
product name
Compact NSX
product or component type
Circuit breaker
device short name
Compact NSX160F
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
network frequency
50/60 Hz
[In] rated current
160 A at 40 °C
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ue] rated operational voltage
690 V AC 50/60 Hz
Breaking capacity code
F 36 kA 415 V AC
breaking capacity
10 kA at 600 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit protection functions
LI
pollution degree
3 conforming to IEC 60664-1
Complementary
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
auxiliary contact composition
Without
mechanical durability
40000 cycles
electrical durability
10000 cycles 440 V In/2 conforming to IEC 60947-2
15000 cycles 690 V In/2 conforming to IEC 60947-2
20000 cycles 440 V In conforming to IEC 60947-2
7500 cycles 690 V In conforming to IEC 60947-2
connection pitch
35 mm
local signalling
Positive contact indication
protection type
L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
trip unit rating
160 A at 40 °C
long time pick-up adjustment type Ir
Adjustable
long time pick-up adjustment range
0.7…1 x In
long time delay adjustment type
Fixed
[tr] long-time delay adjustment range
120…400 s at 1.5 x In
15 s at 6 x Ir
short-time pick-up adjustment type Isd
Fixed
[Isd] short-time pick-up adjustment range
1250 A
short-time delay adjustment type
Fixed
height
161 mm
width
105 mm
depth
86 mm
net weight
2.2 kg
compatibility code
NSX160
Environment
overvoltage category
Class II
electrical shock protection class
Class II
standards
EN/IEC 60947
UL 508
product certifications
EAC
CCC
Marine
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
ambient air temperature for operation
-35…70 °C
ambient air temperature for storage
-55…85 °C
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information
Yes
Categories: , Tags: , , , ,
range
Compact
product name
Compact NSX
product or component type
Circuit breaker
device short name
Compact NSX160F
device application
Distribution
poles description
3P
protected poles description
3t
network type
AC
network frequency
50/60 Hz
[In] rated current
160 A at 40 °C
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ue] rated operational voltage
690 V AC 50/60 Hz
Breaking capacity code
F 36 kA 415 V AC
breaking capacity
10 kA at 600 V AC 50/60 Hz conforming to UL 508
85 kA at 240 V AC 50/60 Hz conforming to UL 508
22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
35 kA at 480 V AC 50/60 Hz conforming to UL 508
30 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity
35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation
Yes conforming to EN 60947-2
Yes conforming to IEC 60947-2
utilisation category
Category A
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit protection functions
LI
pollution degree
3 conforming to IEC 60664-1
Complementary
control type
Toggle
mounting mode
Fixed
mounting support
Backplate
upside connection
Front
downside connection
Front
auxiliary contact composition
Without
mechanical durability
40000 cycles
electrical durability
10000 cycles 440 V In/2 conforming to IEC 60947-2
15000 cycles 690 V In/2 conforming to IEC 60947-2
20000 cycles 440 V In conforming to IEC 60947-2
7500 cycles 690 V In conforming to IEC 60947-2
connection pitch
35 mm
local signalling
Positive contact indication
protection type
L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
trip unit rating
160 A at 40 °C
long time pick-up adjustment type Ir
Adjustable
long time pick-up adjustment range
0.7…1 x In
long time delay adjustment type
Fixed
[tr] long-time delay adjustment range
120…400 s at 1.5 x In
15 s at 6 x Ir
short-time pick-up adjustment type Isd
Fixed
[Isd] short-time pick-up adjustment range
1250 A
short-time delay adjustment type
Fixed
height
161 mm
width
105 mm
depth
86 mm
net weight
2.2 kg
compatibility code
NSX160
Environment
overvoltage category
Class II
electrical shock protection class
Class II
standards
EN/IEC 60947
UL 508
product certifications
EAC
CCC
Marine
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
ambient air temperature for operation
-35…70 °C
ambient air temperature for storage
-55…85 °C
Offer Sustainability
Sustainable offer status
Green Premium product
REACh Regulation
EU RoHS Directive
Mercury free
Yes
RoHS exemption information

Reviews

There are no reviews yet.

Be the first to review “Circuit breaker Compact NSX160F, 36 KA at 415 VAC, TMD trip unit 160 A, 3 poles”

Your email address will not be published.

Shopping Cart